ISO 9001 : 2008

CERTIFIED

VAV B 20/30 Series

Dual Duct Type

Type: Rectangular / Round

Construction: Galvanized Steel (GI) / Stainless Steel

Application: Light & Medium Duty

 

Dual Duct Terminals
Dual duct terminal units are used in a special type of air distribution system where the main system has both warm air and cold air separatly ducted to each termial unit. the flow of both warm air and cool air is modulated, delivering air to the VAV zone at variable air volumes as well as variable temperatures.

 

A dual duct with integral mixing is similar to the non-mixing type, but has an integral mixing section between the two supply valves and the discharge duct connection. The standard mixing dual duct should provide, at a downstream distance of three equivalent diameters from the dual duct, a uniform discharge air temperature profile (±1 °F).

Technical Features:

  • Volume control range from 100 to 10% is possible to the
    conditioned zone.
  • Accurate airflow sensing with 2 X 12 points averaging.
    Low Leakage i.e. less than 2% of V nominal at 750 Pa.
  • Designed to produce low NC levels with minimal
    pressure drop to the system.
  • Suitable for use as constant volume application,it can
    maintain a set flow requirement, compensating for
    fluctuations in system pressure.
  • Suitable for single duct variable volume control
  • Air volume capacity upto 2800 CFM
  • Electronics control factory supply & mounted.
  • Variety of control options available, based on
    applications.
  • Electronic thermostat & actuator provide accurate
    mounting control.
  • Metal encapsulated edges limit fiberglass insulation
    erosion into the airstream.
  • Single-point power connection reduces installed cost.
  • Maintenance free.
  • Mixing dual ducts are used in both interior and exterior
    zones in buildings such as hospitals, or buildings where
    the use of auxiliary reheat such as hot water or electric
    reheat is not desirable.

Standard construction

Casing

0.9 mm thick galvanized sheet steel.

Insulation

13 mm thick 32 kg/m³ density Acoustic liner.

Blade

0.9 mm thick galvanized sheet steel.

Flow grid

Flow grid multi point with 12 inlet holes in four concentric
circles.

Axle Shaft

12 mm diameter axle shaft made of galvanized steel.

Bearings :

12 mm diameter Brass bearings.

Gasket

Neoprene Gasket.

Controls :

Modulating / On-Off

Optional Construction

Controls

Backnet DDC with suitable thermostat.

Sound Attenuator

VAV with additional length insulated casing for sound
attenuation.

Insulation

25 mm thick 32 kg/m³ density Acoustic liner.

Blade

0.9 mm thick aluminium extruded aerofoil multiple blades.

Duct Heater

Slip-in type electric duct heater (230V AC 1 Phase or 400VAC 3 Phase)

Double skin

Insulated internal walls surface with Galvanized perforated
sheet used for low noise applications to minimise breakout
noise.

Neck connections

Round inlet with round outlet and square inlet with square
outle

Downloads

Request for Quotation

  • MSFD-GB-31C3-A-R

    Galvanized construction, 3-hour, Class 3 leakage at 350° F, 3V single skin blade, 4 in. wg, 2000 fpm, operating temperature 250° C up to 2 hours
    Read more
  • MSFD-GB-31C2-A-R

    Galvanized construction, 3-hour, Class 2 leakage at 250° F, 3V single skin blade, 4 in. wg, 2000 fpm, operating temperature 250° C up to 2 hours
    Read more
  • MSFD-GB-31C1-A-R

    Galvanized construction, 3-hour, Class 1 leakage at 250° F, 3V single skin blade, 4 in. wg, 2000 fpm, operating temperature 250° C up to 2 hours
    Read more