ISO 9001 : 2008

CERTIFIED

VAV B 60 Series

Type: Rectangular / Round

Construction: Galvanized Steel (GI)

Application: Light & Medium Duty

 

Fan Powered VAV Model VAV-GB-61 is parallel fan powered terminal unit features intermittent parallel fan operation. Fan Powered VAV B-61 is “designed to-maintain optimum occupant comfort levels by supplying warm induced plenum air, cold primary air (VAV) or a mixture of both to condition the space.

 

Fan-powered parallel units offer energy savings due to intermittent fan control. The fan energizes only in heating mode when the space needs heat. Additional energy savings are obtained by using warm plenum air for free reheat. Motor heat is never wasted in parallel units. They are an excellent choice when minimal zone heating is needed

Technical Features:

  • Fan on during heating
  • Sized to handle heat air flow
  • Higher supply pressure
  • Variable sound and air flow
  • Metal encapsulated edges limit fiberglass insulation
    erosion into the airstream.
  • Single-point power connection reduces installed cost.
  • Fan is outside primary airstream and runs only when
    heating is required.
  • Wide range of fan airflows available from single speed
    motor with speed control.

Standard construction

Casing

0.9 mm thick galvanized sheet steel.

Insulation

25 mm thick 32 kg/m³ density Acoustic liner.

Blade

0.9 mm thick galvanized sheet steel.

Flow grid

Flow grid multi point with 12 inlet holes in four concentric circles.

Axle Shaft

12 mm diameter axle shaft made of galvanized steel.

Bearings

12 mm diameter Brass bearings.

Gasket

Neoprene Gasket.

Controls

Modulating / On-Off.

Optional Construction

Controls

Backnet DDC with suitable thermostat.

Duct Heater

Slip-in type electric duct heater (230V AC 1 Phase or 400VAC 3 Phase)

Double skin

Insulated internal walls surface with Galvanized perforated
sheet used for low noise applications to minimise breakout
noise.

Neck connections

Round inlet with round outlet and square inlet with square
outlet.

Downloads

Array

Request for Quotation

  • MSFD-GB-31C3-A-R

    Galvanized construction, 3-hour, Class 3 leakage at 350° F, 3V single skin blade, 4 in. wg, 2000 fpm, operating temperature 250° C up to 2 hours
    Read more
  • MSFD-GB-31C2-A-R

    Galvanized construction, 3-hour, Class 2 leakage at 250° F, 3V single skin blade, 4 in. wg, 2000 fpm, operating temperature 250° C up to 2 hours
    Read more
  • MSFD-GB-31C1-A-R

    Galvanized construction, 3-hour, Class 1 leakage at 250° F, 3V single skin blade, 4 in. wg, 2000 fpm, operating temperature 250° C up to 2 hours
    Read more